Formal specifications are used to develop an abstract view of the system without going into the details of implementation (Partsch, 2012). This assists in developing a clear logic, in a precise manner, of how the system will operate. This is achieved through the employment of mathematical notations borrowed from formal logic and the set theory (Sommerville, 2013). Consequently, formal specifications reduce the development costs and ambiguity during system development (Sommerville et al., 2012).
The formal specification technique known as Z notation models the behaviour of the proposed system. It does so by decomposing the system into small units which are known as schemas. Mathematical notations from the set theory and predicate logic are used to model the schemas (Klein, Sawicki, Roos-Frantz & Frantz, 2014). These schemas represent the static and dynamic aspects of the proposed system. Static aspects are the possible states the system may be in at any given time (state space) andEffective Workplace Relationships between those states.
A typical schema consists of a title, declaration part, where variables are declared, and a predicate part. The predicate section defines conditions which must be met during operation and the relationship between variables and functions. The figure below illustrates:
SchemaName
Variable declarations
Predicate(s)
The predicate part is optional and is assumed to be true when absent.
The Z notations used for the library system schema include:-
1.?- Declares a variablexto be a subset ofY.Its syntax isx:?Y
2.?- Indicates partial dependence of a variableyon a variablex.The syntax is of the formx?y
3.Δ–It is known as a delta and shows that the current function causes a change in system state, for example when a new item is added.
4.Ξ– It is known as Xi and indicates that the current function does not alter system state
5.∪-Indicates a union between set A and B. Technically, it represents an addition of an element to a set X in a schema
6.∈- Indicates that an elementxis a member of a setY. Its syntax isx∈Y
7.∉-Indicates that an elementxis not a member of a setY. Its syntax isx∉Y
8.? –Is used to indicate input variablex. The syntax is of the formx?: TYPE
9.! – Is used to indicate output variablex. The syntax is of the formx!: TYPE
The schema below depicts the initial state of the container control system whereby no data has been captured yet. In other words, the system is devoid of any data.
Init
Container_control_system
known=∅
Container_Terminal
known:?NAME
container_capacity:NUMBER
tonnage_capacity:WEIGHT
capacity:container_capacity?tonnage_capacity
known=dom NAME
The schema above depicts the domain (key identifier), which is ‘NAME’ and ranges, which are the variables associated with an instance.
Enter_new_container_terminal
Δ Container_control_system
name? :NAME
container_capacity?:NUMBER
tonnage_capacity?:WEIGHT
name? ∉NAME
NAME′ =NAME∪{name??(container_capacity?,tonnage_capacity?}
The above schema shows that when a new container is added to a terminal the name should not already exist in the terminal relations set. Only then can the system accept the new instance and associated tuple.
delivery
known:?GLOBAL_NO
terminal:NAME
freight_company?SOURCE
quantity:NUMBER
tonnes:WEIGHT
count:INTEGER
vehicle_identifier:IDENTIFICATION
current_deliveries:INTEGER
known=dom GLOBAL_NO
The above schema depicts the deliveries domain and associated ranges. These are the key identifier (GLOBAL_NO) and the variables associated with an instance.
Accept_delivery
ΔContainer_control_system
id?:GLOBAL_NO
terminal? :NAME
freight_company?:SOURCE
quantity?:NUMBER
tonnes?:WEIGHT
count?:INTEGER
truck_registration?:REGISTRATION
current_deliveries?:INTEGER
current_quantity:NUMBER
current_tonnage:WEIGHT
message!: REPORT
id?∉known
if current_quantity==container_capacity∨current_tonnage==tonnage_capacity then
message=capacity_full
if((quantity+current_quantity)>container_capacity)∨((tonnes+current_tonnage)>tonnage_capacity)
then
message=capacity_exceeded
if current_deliveries==5then
message=queue_delivery
else
known′ =known∪{id? ?terminal??freight_company??quantity??tonnes?count
?vehicle_identifier}
Message=success
In the above schema, the delivery instance should not already exist in the system. The information system first checks if the terminal’s capacity is full, in terms of either quantity or tonnage and displays an error message if the condition is met. It then checks if the terminal’s capacity will be exceeded, also in terms of either quantity or tonnage when the new delivery is added and displays an error message if the condition is met. Finally, the system checks if the delivery trucks currently beingprocessed are five in number and queues the incoming delivery if the condition is met.
pickup
known:?GLOBAL_NO
terminal:NAME
truck_registration:REGISTRATION
freight_company?DESTINATION
quantity:NUMBER
tonnes:WEIGHT
count:INTEGER
current_pickups:INTEGER
known=dom GLOBAL_NO
The schema above the domain and ranges of the pickup state space, that is, the key identifier (GLOBAL_NO) and associated variables respectively.
Accept_pickup
ΔContainer_control_system
id?:GLOBAL_NO
terminal? :NAME
truck_registration?:REGISTRATION
freight_company?:SOURCE
quantity?:NUMBER
tonnes?:WEIGHT
count?:INTEGER
current_pickups?:INTEGER
message!: REPORT
id∉known
if current_pickups==5then
message=queue_pickup
else
known′=known∪{id??(terminal?,truck_registration?,freight_company?,quantity?,tonnes?,count?)}
Message=success
The above schema shows that when pickups currently ongoing involves five trucks, then the pending pickup is queued by the system. Otherwise, the new pick up is captured and stored and a success message displayed.
ships
known:?NAME
nationality: SOURCE
containers: INTEGER
tonnage: WEIGHT
known=dom NAME
The above schema depicts the ships state space with its domain (key identifier) and ranges (variables).
Unload-ship
ΔContainer_control_system
name:NAME
terminal:NAME
quantity:INTEGER
tonnage:WEIGHT
container_capacity:INTEGER
tonnage_capacity:WEIGHT
message!:REPORT
if deliveries_not_finished∧pickups_not_finished then
message=deliveries_and_pick_ups_not_finished
if(quantity>container_capacity)∨(tonnage>tonnage_capacity)then
message=capacity_exceeded
The above schema shows that when all deliveries and pickups are not finished, no unloading should take place. Furthermore, if the containers’ quantity or tonnage exceeds the terminal's capacity the system displays an error message.
Container_terminal_account
ΞContainer_control_system
total_quantity:INTEGER
total_tonnage:WEIGHT
count!:INTEGER
report!:total_quantity?total_tonnage
count! (i…n): CONTAINER|report!
Ships-total-account
ΞContainer_control_system
total_quantity:INTEGER
total_tonnage:WEIGHT
count!:INTEGER
report!:total_quantity?total_tonnage
count! (i…n): CONTAINER|report!
Freight-company-account
ΞContainer_control_system
total_quantity:INTEGER
total_tonnage:WEIGHT
count!:INTEGER
report!:total_quantity?total_tonnage
count! (i…n): CONTAINER|report!
REPORT ::=capacity_full|capacity_exceeded|queue_delivery|success|queue_pickup|deliveries_and_pick_ups_not_finished|incorrect_registration
capacity_full
result!: REPORT
result!=capacity_full
capacity_exceeded
result!: REPORT
result!=capacity_exceeded
queue_delivery
result!:REPORT
result!:queue_delivery
success
result!: REPORT
result!:success
queue_pickup
result!: REPORT
result!:queue_pickup
deliverie_pickups_not_finished
result!:REPORT
result!: deliverie_pickups_not_finished
incorrect_registration
result!:REPORT
result!:incorrect_registration
From research findings, formal specification techniques are extremely useful when it comes to the engineering of large, complex systems. They are extremely useful tools in the software and industrial engineering disciplines. Research and improvements are ongoing as they continue to be more defined and developed.
1.Klein, M. J., Sawicki, S., Roos-Frantz, F., & Frantz, R. Z. (2014, April). On the Formalisation of
2.an Application Integration Language Using Z Notation. In ICEIS (1) (pp. 314-319).
3.Partsch, H. A. (2012). Specification and transformation of programs: a formal approach to software testing. Springer Science & Business Media.
4.Sannella, D., & Tarlecki, A. (2012). Foundations of algebraic specification and formal software
5.development. Springer Science & Business Media.
6.Singh, M., Sharma, A. K., & Saxena, R. (2016). Formal Transformation of UML Diagram: UseCase, Class, Sequence Diagram with Z Notation for Representing the Static and Dynamic Perspectives of System. In Proceedings of International Conference on ICT for Sustainable Development(pp. 25-38). Springer, Singapore.
7.Smith, G. (2012). The Object-Z specification language (Vol. 1). Springer Science & Business Media.
8.Smith, G. (2012). The Object-Z specification language (Vol. 1). Springer Science & BusinessMedia.
9.Sommerville, I. (2013). Software Engineering: Pearson New International Edition. PearsonEducation Limited.
10.Sommerville, I., Cliff, D., Calinescu, R., Keen, J., Kelly, T., Kwiatkowska, M., ... & Paige, R.(2012). Large-scale complex IT systems. Communications of the ACM, 55(7), 71-77.
11.Woodcock, J. (2014). Software engineering mathematics. CRC Press.